Industrial Equipment Search

Can't find what you're looking for. Click Add Custom Item and provide a description of the item you are looking for. It will then be added to your quote cart.

  AC Motors

Single Phase, TEFC

  • High-Torque design for tough applications such as farm-duty
  • 1.15 SF through 10HP
  • Oversized ball bearing
  • Manual reset overload protector installed with rubber boots/gasket
  • Rugged cast-iron frame and endbells 143T through 215T
  • Oversized and gasketed conduit box
  • Non-hygroscopic insulation system
  • Zn-Cd plated hardware
  • Dynamically balanced pressure die-cast aluminum rotor
  • Ground terminals
  • Condensation drain holes


Rolled Steel ODP EPACT

  • AC, 3 phase, 60Hz, 208-230/460V, 1.15 SF; also rated for 50Hz at 1.0 SF on nameplate (50Hz, 190/380V)
  • Usable on 200V, 60Hz
  • NEMA Design B performance; exceeds the requirements of EPACT with DOE certified
  • UL recognized Class F non-hygroscopic insulation system with HPETM - High Pulse Endurance spike resistant wire for inverter applications
  • Class B temperature rise
  • Multiple mountings for 56 and 140T; dual mountings for frame 180T~280T
  • Interchangeable F1 and F2 mounting for frame 180T~280T
  • Bi-directional rotation
  • 90 degree rotatable oversized and gasketed conduit box
  • Stainless steel nameplate
  • Accepts C-face conversion kit
  • Three year warranty


Rolled Steel ODP JM & JP EPACT

  • AC, Three phase, 60Hz, 208-230/460V, 1.15 S.F.; also rated for 50Hz at 1.0 S.F. on nameplate (50Hz, 190/380V)
  • Usable on 200V, 60Hz
  • NEMA Design B performance; exceeds the requirements of EPACT with DOE certified
  • UL recognized Class F non-hygroscopic insulation system with HPETM - High Pulse Endurance spike resistant wire for inverter applications
  • Class B temperature rise
  • Interchangeable F1 and F2 mounting for frame 180T~280T
  • Bi-directional rotation
  • 90 degree rotatable oversized and gasketed conduit box
  • Stainless steel nameplate
  • Three year warranty


High Efficiency ODP

  • HPETM - High Pulse Endurance Wire
  • Premium efficiency and high power factor
  • Corrosion resistant hardware
  • Lead lugs on 143T to 449T frame
  • Neoprene lead separator
  • F-1 and F-2 mounting interchangeability
  • C-Flange, D-Flange and P-Base kits available for 254T to 449T frame
  • Fully tested and documented per IEEE 112, Method B and NEMA MG-1
  • Class B temperature rise
  • 1.15 service factor
  • Suitable for 208V operation from 1HP to 125HP
  • Suitable for wye-delta starting from 7.5HP to 400HP (12 leads for 7.5HP to 125HP, 6 leads for 150HP to 400HP)
  • Suitable for VFD service 5:1 constant torque, 20:1 variable torque
  • 6 Leads only on 575 Volt


Oil Well Pump ODP

  • NEMA Design D, 5-8% slip
  • Cast-Iron Frame, End Brackets and Oversized Conduit Box
  • Fully guarded with Rodent Screen
  • Oversized Bearings selected for Belt-drive application
  • Grounding Terminals on Frames and Inside Conduit Box
  • Thermal Protectors embedded in Winding in each Phase
  • Stainless Steel Nameplate
  • F2 Mounting


3 Phase Fractional HP, TEFC

  • Heavy Gauge Steel Frame With Condensation Drain Holes
  • Ribbed Die-Cast Aluminum Endbells With Machined Steel Bearing Seat and Shaft Slinger
  • Large Size Double-Gasketed 90 Degree Rotatable Conduit Box
  • Oversized Vacuum De-Gassed Ball Bearing
  • High-Grade Insulated Electro-magnetic Steel Stator With Polyester Enameled Copper Wire
  • Cast-Iron C-Face Kit For Rigid Base Mount Motors
  • Cd-Zn plated Corrosive-Resistant Hardware


MAX-SE®, EPACT TEFC

  • AC, 3 phase, 60Hz, 230/460V (usable on 208V); 460V and 575V. 50Hz and other voltage under 600V are also available upon request
  • Motors are dual nameplated for 60Hz and 50Hz
  • NEMA Design B and C performance
  • MAX-SE® (type AEEANE) EPACT motors meet or exceed the requirements of EPACT 1992
  • UL recognized Class F non-hygroscopic insulation system with heavy heat resistance enameled copper wire to provide longer winding life and reliability
  • Continuous rated at 1.15 service factor


MAX-SE C-FACE®, EPACT TEFC

  • AC, 3 phase, 60Hz, 230/460V (usable on 208V); 460V and 575V. 50Hz and other voltage under 600V are also available upon request
  • Motors are dual nameplated for 60Hz and 50Hz
  • NEMA Design B and C performance
  • MAX-SE® (type AEEANE) EPACT motors meet or exceed the requirements of EPACT 1992
  • UL recognized Class F non-hygroscopic insulation system with heavy heat resistance enameled copper wire to provide longer winding life and reliability
  • Continuous rated at 1.15 service factor


MAX-HT® High Torque Crusher Motor, TEFC

  • 3 Phase, 60Hz, 460V (6 leads)
  • Premium efficiency design
  • Suitable for Across the Line Starting and Y- Delta Starting
  • NEMA Design C (Locked Rotor Torque =200% FLT; Breakdown Torque =250% FLT)
  • Class F insulation with class B rise
  • Moisture resistant copper – 2DIPs & BAKEs with Epoxy resin and 1-spray Enamel top coating for abrasion resistance
  • Thermal protection (thermistors, one per phase)
  • Squirrel-cage, Aluminum conductor with end-ring and wafer blades integrally cast rotor for all frame sizes (F#5007-5808)


MAX-E1® High Efficiency - Severe Duty, TEFC

  • HPE™ - High Pulse Endurance Wire
  • Non-hygroscopic, Class F insulation system
  • High-grade, electro-magnetic steel laminations for low core loss and high efficiency
  • All cast-iron construction including IP55 frame, end brackets, fan cover and conduit box for rigidity and excellent corrosion resistance
  • Reinforced end turn lacing
  • Neoprene lead separator
  • High performance bearings of degassed steel
  • 90° rotatable oversized cast iron conduit box for easy connection
  • Corrosion-resistant non-sparking external fan


MAX-E2® NEMA Premium Efficiency - Severe Duty, TEFC

  • Designed to meet NEMA MG-1, MG-13
  • Stock available in 460V and 575V; other voltages available upon request
  • Premium efficiency; meets or exceeds NEMA PREMIUM, EPACT ‘92 and Canadian Federal Efficiency Levels defined in CSA C390-93; Full load efficiency of all ratings is certified under the EEV Program of the CSA
  • Motors are NEMA Design “B” and "C" Torque
  • UL recognized Class F non-hygroscopic insulation system with HPE™ (High Pulse Endurance) index, heavy heat resistance enameled copper wire ensures longer winding life and reliability
  • CSA certified for Class1, Division 2, Groups B, C and D with Temperature Code T3C
  • Class B temperature rise, 80°C rise by resistance method at 1.0 SF; 90°C rise at 1.15 SF
  • 3 Leads solderless lug terminals


MAX-E2/841® NEMA Premium Efficiency - Severe Duty, TEFC

  • Designed to meet NEMA MG-1, MG-13 and IEEE 841
  • Stock available in 460V and 575V; other voltages available upon request
  • Premium efficiency; meets or exceeds the requirements of EPACT '92 and Canadian Federal Efficiency Levels defined in CSA C390-93; Full load efficiency of all ratings is certified under the EEV Program of the CSA
  • UL recognized Class F non-hygroscopic insulation system with HPE™ (High Pulse Endurance) index, heavy heat resistance enameled copper wire insures longer winding life and reliability
  • CSA certified for Class 1, Division II, Group B, C and D with Temperature Code T3C
  • Class B temperature rise, 80°C rise by resistance method at 1.0 S.F.; 90°C rise at 1.15 SF
  • 3 Leads solderless lug terminals
  • Meets GM 7E-TA specifications


MAX-E1/31® High Efficiency - Inverter Duty, TEFC

  • Insulated bearing for 324TS frames and larger to eliminate shaft currents
  • HPETM - High Pulse Endurance Wire
  • Non-hygroscopic, Inverter-grade insulation
  • High-grade, electro-magnetic steel laminations for low core loss and high efficiency
  • All cast-iron construction including frame, end brackets, fan cover and conduit box for rigidity and excellent corrosion resistance
  • Reinforced end turn lacing
  • Neoprene lead separator
  • 90° rotatable oversized cast iron conduit box for easy connection
  • Service factor 1.0 on PWM power


High Efficiency Washdown, TEFC

  • All exterior surfaces are finished with USDA approved two part epoxy paint to protect against rust, corrosion and chemical attack, and meeting the sanitary requirements
  • Double Sealed oversized bearings with Chevron SRI-2 type or equivalent high temperature/moisture resistant greases for longer bearing life
  • Contact lip seal and V-ring on both endbell and C-face protect both bearings from moisture
  • Corrosion resistant cast iron C-face for rigidity
  • Stainless steel hardware to prevent rust and corrosion
  • Drain holes in frame, endbell and C-face to allow condensation to drain
  • Threaded and fully gasketed stainless steel (2HP and below)/cast iron (3-10HP) oversized conduit box to seal out moisture
  • No. 304 stainless steel shaft and special rotor rust-resistant treatment


Closed Couple Pump JM & JP, TEFC

  • Class F insulation with Class B temperature rise
  • Cast iron frame and endbells
  • Copper windings
  • Oversized ball bearings
  • Conversion Kits CHEM-DUTY Kits
  • Continuous SF 1.15 or 1.0


TEXP HE, High Efficiency Explosion Proof, TEFC

  • HPE™ – High Pulse Endurance Wire
  • Rugged Cast-Iron Construction
  • Non-Sparking External Fan
  • Non-Sparking Brass Flingers on Both Ends
  • Oversized Cast-Iron Conduit Box
  • Non-hygroscopic Insulation System
  • Zn-Cd Plated Hardware
  • Stainless Steel Breather/Drains with Bronze Filter
  • Low Temperature Rise Operation
  • Stainless Steel Rating Nameplate and CSA Label
  • Bi-Directional Rotation


Metric, High Efficiency, TEFC/IP55

  • Premium efficiency; exceeds the federally legislated efficiency levels of EPACT 1992
  • With CE mark complying with EU Standards and Directives
  • Class F insulation with Class B temperature rise
  • Winding thermistor installed for frames D160 and larger
  • Wye-Delta start capability for 4 KW (5.5HP) and larger
  • Electrical flexibility with dual Hz, multiple volts/amps shown on nameplate
  • 230/460V at 60Hz. and 190/380V at 50Hz.
  • IP55 Protection with tapped shaft end
  • F-2 mounting
  • Oversized bearings


Global Series, Low Voltage, TEFC

  • Design Standard: NEMA MG-1; MG-13; NEMA Design B (3600 RPM) and NEMA Design C (1800, 1200 RPM)
  • Conversion Kits: C-Face, D-Flange and P-Base
  • Class F insulation
  • All cast-iron construction including conduit box, fan and fan cover (heavy gauge steel fan cover for frames 5806 and larger)
  • Copper windings
  • Oversized ball/roller bearings
  • Minimum 250% breakdown torque (except 3600 RPM)


Global Series, Low Voltage, ODP

  • Design Standard: NEMA MG-1; MG-13; NEMA Design B
  • Conversion Kits: C-Face, D-Flange, and P-Base
  • Class F insulation with Class B temperature rise
  • Cast-iron frame through 449T(S) and extra heavy gauge steel frame for frames 5007and larger
  • Cast-iron end bells and conduit boxes for all ratings
  • Copper windings
  • Oversized ball/roller bearings
  • Minimum 250% breakdown torque (except 3600 RPM)


Global Series, Medium Voltage, TEFC

  • Design Standard: NEMA MG-1; MG-13; NEMA Design B and C (1800 and 1200 RPM)
  • Conversion Kits: please contact factory
  • Class F insulation
  • All cast-iron construction (heavy gauge steel fan cover for frames 5806 and larger)
  • Copper bar rotor (for frames 5007 and larger)
  • Standard built-in winding RTDs and space heaters
  • Meets most chemical/severe duty application requirements
  • Oversized ball/roller bearings
  • Vacuum Impregnated Form Wound Coils (VPI)


Global Series, Medium Voltage, ODP/WP1

  • Design Standard: NEMA MG-1; MG-13; NEMA Design B
  • Conversion Kits: please contact factory
  • Class F insulation
  • Cast-iron frame
  • Cast-iron end bells and conduit boxes for all ratings
  • Oversized ball/roller bearings
  • Standard built-in winding RTDs and space heaters
  • Copper bar rotor (for frames 5007 and larger)
  • Vacuum Impregnated Form Wound Coils (VPI)


Premium Efficiency, Medium Voltage, Global Series, TEFC

  • AC, 3 phase
  • Available in TEFC (IP55) enclosure
  • Continuous rating with 1.15 service factor
  • All Global Series motors are designed to meet or exceed NEMA Design B torque requirements
  • Cast-Iron Construction
  • Copper Bar Rotor
  • 100 OHM Platinum Stator RTD's and 120 Volt Space Heater


  Drives and Controls

Low Voltage FM50

  • Micro AC Inverter
  • Low Cost
  • Space Saving Design
  • NEMA 4 Option for Harsh Environments
  • UL/cUL/CE Approved


Low Voltage FM100

  • Compact 1/2 to 30 HP AC Inverter
  • Low Cost
  • Keypad Mounted Potentiometer
  • Maximum Output Frequency Up To 400 Hz.
  • UL/cUL/CE Approved


Low Voltage GA7200

  • General Purpose AC Inverter
  • Low Cost V/Hz Design
  • Proven Reliability
  • UL/cUL/CE Approved
  • 230V Series 1 - 100HP
  • 460V Series 1 - 450HP


Low Voltage MA7200

  • English LCD Display /Copy Unit
  • Modbus Communication (Built-in)
  • Profibus Communication (Optional)
  • PG Feedback (Built-in)
  • PID Function
  • Simple PLC Function
  • Timer Function
  • Energy Savings Function


Low Voltage SA6

  • Compact
  • Low Horsepower
  • Reduced Voltage Starter
  • Dual Starting Mode Current Limit or Current Ramp
  • Heatsink Overtemperature Detection and Shutdown (above Size 18)
  • Run Relay Output Form C Rated 1 Amp at 240VAC
  • 1600V PIV SCR’s with MOV Surge Induction Motors
  • 3 Phase Current Feedback and Monitoring
  • 6 SCR Fully Controlled Power Circuit
  • Low Cost


Low Voltage SA7

  • Advanced Solid-State Reduced
  • Voltage Motor Starter
  • Torque Ramp for Linear Acceleration
  • Dynamic Motor Mapping Fine
  • Simple Setup for the Majority
  • Enhanced Setup for the More Demanding Applications
  • Serial Communications
  • Forward / Reverse Jogging
  • Complete Monitoring Package Eliminates Need for Add On Devices
  • Extensive Protection Features for Motor and Starter
  • Rugged Compact Design
  • Available From 7.5 HP to 1000 HP (460V)